CABLING VIA DISTRIBUTION POINT

Cabling from wall box, via distribution point, to panel in technical room. A 2-fiber, pre-terminated, white subscriber cable is used from the wall box to the distribution point. From the distribution point to the panel in the technical room, an MPO cable with 12 or 24 fibers is used. The transition from LC/PC to MPO in the distribution point is built into a BUDI wall box. Here cables enter via a slotted opening in the bottom and are plugged internally into the BUDI wall box.



MPO is a multi-fiber connector where you can easily connect 12 or 24 fibers in one connector. When using a 12-fiber MPO cable, you can connect up to 6 subscriber wall boxes to the distribution point. With a 24-fiber MPO cable, up to 12 subscribers per distribution point. Excess length of subscriber cable must be handled at the distribution point in a coil management frame.

Excess length of MPO cable is handled in the technical room either with storage units in the panels or in a coil management frame. In the technical room, the patch panel will handle the transition from MPO to LC/PC, and you will have LC/PC duplex connectors in the front panel.

The subscriber wall box with pre-terminated cable is of the same type as for the solution for direct cabling. Since a 2-fiber cable with connectors is used, the Plug & Play solution can be easily used in both 1-fiber and 2-fiber communication solutions.


SUBSCRIBER WALL BOX

The subscriber wall box with pre-terminated cable is delivered on a cardboard box with a drum and the wall box connected to the inner end of the cable. After measuring the cabling lengths, you can order different lengths of cable on the drums. An excess length must be added in the order. This excess length is handled in the technical room either with storage units in the panels or in a coiling management frame.

Wall box FTH, 2 SC/APC, 9/OS2/4500, 5 m, white

CommScope HFTP wall box (CK7246-000) with 2 SC/APC (CK7246-000) and bend resistant fiber according to ITU-T G.657.A2

CK7246-2SSCA-050-E
Wall box FTH, 2 SC/APC, 9/OS2/4500, 15 m, white

CommScope HFTP wall box (CK7246-000) with 2 SC/APC (CK7246-000) and bend resistant fiber according to ITU-T G.657.A2

CK7246-2SSCA-150-E
Wall box FTH, 2 SC/APC, 9/OS2/4500, 30 m, white

CommScope HFTP wall box (CK7246-000) with 2 SC/APC (CK7246-000) and bend resistant fiber according to ITU-T G.657.A2

CK7246-2SSCA-300-E
Wall box FTH, 2 SC/APC, 9/OS2/4500, 50 m, white

CommScope HFTP wall box (CK7246-000) with 2 SC/APC (CK7246-000) and bend resistant fiber according to ITU-T G.657.A2

CK7246-2SSCA-500-E


WALL BOX FOR THE DISTRIBUTION POINT

BUDI-1S wall box prepared for Plug & Play. The DIN Mini inside comes fully connected with MPO and are mounted on the bracket inn BUDI-1S. The cables are taken into a entry slot in the bottom for easy intake of pre-terminated cable.

Wall box BUDI-1S, Plug&Play

CX0193-PP
Wall box DIN MINI, 12xLC/PC-1x12 MPOAM OS2, A

A compact distribution box for fiber optics with pre-installed singlemode MPO to LC fan-out for DIN-rail mount or directly on wall. Both the lid and the adapter plate may be removed, making simple access for working in the box. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FPD66-12SLC-MPOA-A
Wall box DIN MINI, 24xLC/PC-1x24 MPOAM OS2, A2

A compact distribution box for fiber optics with pre-installed singlemode MPO to LC fan-out for DIN-rail mount or directly on wall. Both the lid and the adapter plate may be removed, making simple access for working in the box. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FPD66-24SLC-MPOA-A2T


CABLE MANAGEMENT FRAME

Cable management frame, universal

Adjustable cable management frame suitable for both small and large closures. The slim profile minimizes visibility.  

402771
Pole bracket, iron pole, aluminum

402771-1


MPO CABLE


MPO connectors usually have 12 or 24 fibers in each connector. You should measure the length and add some extra margin.

Cable, 24xOS2 I/P MPOAF-MPOAF, 2 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-BIRR-0020-AT
Cable, 12xOS2 I/P MPOAF-MPOAF, 5 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-AIRR-0050-A
Cable, 12xOS2 I/P MPOAF-MPOAF, 10 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-AIRR-0100-A
Cable, 12xOS2 I/P MPOAF-MPOAF, 2 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-AIRR-0020-A
Cable, 24xOS2 I/P MPOAF-MPOAF, 5 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-BIRR-0050-AT
Cable, 24xOS2 I/P MPOAF-MPOAF, 10 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-BIRR-0100-AT
Cable, 24xOS2 I/P MPOAF-MPOAF, 20 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-BIRR-0200-AT
Cable, 12xOS2 I/P MPOAF-MPOAF, 20 m, A

Single mode cable with MPO/APC-Female connectors - polarity A

8-AIRR-0200-A

TECHNICAL ROOM

Panels and modules

Panel FP65, 12xLC/PC-1x12 MPOAM, OS2, A

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-12SLC-MPOA-A
Panel FP65, 24xLC/PC-2x12 MPOAM OS2, A

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-24SLC-2MPOA-A
Panel FP65, 48xLC/PC-4x12 MPOAM OS2, A

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-48SLC-4MPOA-A
Panel FP65, 24xLC/PC-1x24 MPOAM OS2, A1

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-24SLC-MPOA-A1T
Panel FP65, 48xLC/PC-2x24 MPOAM OS2, A1

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-48SLC-2MPOA-A1T
Panel FP65, 96xLC/PC-4x24 MPOAM OS2, A1

MPO fiber patch panel 1U with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FP65-96SLC-4MPOA-A1T
Module, 12xLC/PC-1x12 MPOAM OS2, A

MPO fiber patch panel with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FPM76-12SLC-MPOA-A
Module, 24xLC/PC-2x12 MPOAM OS2, A

MPO fiber patch panel with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FPM76-24SLC-2MPOA-A
Module, 24xLC/PC-1x24 MPOAM OS2, A1

MPO fiber patch panel with pre-installed MPO to LC fan-out. High density fiber optic management system reduces needed space, deployment time and is easy to use.

FPM76-24SLC-MPOA-A1T
Panel FPM, 3-slot, 1U

The modules can be randomly placed modules for pre-terminated cable, splitters, WDM, CWDM or DWDM. see separate product descriptions for the modules. Can be mounted in 19" cabinets/racks

FPM76105

CABINET

In smaller buildings where the need for capacity is lower, this small wall cabinet is an alternative to a rack. Inside the fiber cabinet it is mounting profiles inn aluminum, this gives an unique flexibility. The mounting profiles can be adjusted in depth and adapted to individual needs. In the cabinet, you can use additional equipment such as bend limiter, routing guide, power outlets, shelves etc.

SOLUTION FOR EXCESS LENGTH OF CABLES

Shelves and storage units, for excess length of cables, are mounted in under the panel.

Shelf, 19", D300 mm, 1.5U

Shelf for network equipment that cannot be screwed directly into data or fiber rack or cabinet. The shelf has holes for better ventilation.

MP452
Shelf retractable, 19", D300 mm, 1U

Shelf retractable for network equipment that cannot be screwed directly into data or fiber rack or cabinet. The shelf has holes for better ventilation.

MP530
Storage unit, 0.5U

Storage unit for mounting under fiber optic panel used for storing excess lengths of patch cords.

FP70310
Storage unit, 0.5U, black

Storage unit for mounting under fiber optic panel used for storing excess lengths of patch cords.

FP70310S

TOOLS FOR ASSEMBLY

One-Click connector cleaner used for professional cleaning of optical connectors. Over 500 cleanings per unit (One-Click). Efficient cleaning of optical connectors can prevent losses and reflections which in turn can cause communication errors. For Plug & Play, this is all the fiber tool you need. An end face fiber microscope can also be used to check the surfaces of the contacts.

Connector cleaner, pen type, OneClick, SC, FC, ST

One-Click connector cleaner used for professional cleaning of optical connectors.

OCC-A
Connector cleaner, pen type, OneClick, LC, MU

One-Click connector cleaner used for professional cleaning of optical connectors.

OCC-B
Connector cleaner, pen type, OneClick, MTP/MPO

One-Click connector cleaner used for professional cleaning of optical connectors. More than 500 cleanings, for MPO/MTP connectors.

MPO-CLK-D
Microscope, digital, P5000i

Digital microscope to inspect fiber connector endfaces. A high quality microscope for inspecting optical connectors and bulkhead connectors. The probe is delivered with FiberChekPRO software for automatic analysis of the connectors end face.

FBP-SD101

Need any help or want to know more?

Feel free to contact us if you need any help choosing the right product for your organization. 
Phone: +47 32 21 08 00
Mail: info@foss-as.no


odkazy
jazyk
používateľské menu